Anaesthesia Machine Diamond Standard

Anaesthesia Machine Diamond Standard Supplied by Anesthesia Products India

Specs:-
The main body is made of High-strength engineering plastic rack, light, beautiful, and corrosion resistant
It can be applied to both Adults & Child
The gas source is O2 & N2O: 0.28~0.6MPa
The flow meter of O2 is 0.05~1.0L/min    1.1~10L/min
N2O: 0.05~1.0L/min   1.1~10L/min
The flow rate of rapid oxygen supply is 25~75L/min
Low oxygen pressure alarm There will be a sound alarm when the oxygen pressure is < 0.2MPa
Vaporizers Among Halothane, Enflurane, Isoflurane, and Sevoflurane, anyone can be chosen for application as required by the customer. The high-precision Vaporizer is designed with a stable concentration output, and automatic compensation for pressure, temperature, and flow rate.
Reliable pneumatic transmission system.
Modularized design and upgrading are available.
The vaporizer has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Respiratory circuit         working mode: all-close, semi-close, semi-open APL:≤12.5kPa
Respiratory bellows for adults and bellows for children are supplied with the Machine
The tidal volume range is 0~1500 ml
Ventilator Specs: Display mode High-definition5.7” LCD screen display
Ventilation  model PPV, SIPPV, SIMV, MANUAL
Ventilation parameters Tidal volume 50~1500ml
Rate               2~99bpm
SIMV               2~20bpm
I:E              2:1~1:8
Inspiratory trigger pressure -10~20cmH2O
PEEP2~20cmH2O
Pressure limitation10~60cmH2O
SIGH 1.5 times the inspiratory time/100bpm
Parameters for ventilation monitoring tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure-time waveform, flow-time waveform, PEEP,  inspiratory trigger pressure,(average pressure, oxygen concentration, battery capacity)
Security Alarm System
Oxygen concentration alarm      upper limit setting range (21%~99%)
low limit setting range    (18%~80%)
Airway pressure alarm upper limit setting range  5~60 cmH2O
Low limit setting range    0~50 cmH2O
Minute ventilation volume alarm  upper limit setting range  1~20 L/min
Low limit setting range    0~19L/min
Tidal volume upper limit setting range  100~1500ml
low limit setting range0~1400ml
A sustained high-pressure alarm will give an alarm when stress has consistently been higher than 2.5cmH2O
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm)
Power  is AC 220V   50Hz
We are Exporters and Suppliers of Anaesthesia Machine Diamond Standard at competitive prices from India.

For More Information, visit us at www.descomedicalindia.com

Model No
APAM 141            Anaesthesia Machine Diamond Standard

Reviews

There are no reviews yet.

Be the first to review “Anaesthesia Machine Diamond Standard”

Your email address will not be published. Required fields are marked *